{"id":652,"date":"2013-11-23T11:05:05","date_gmt":"2013-11-23T11:05:05","guid":{"rendered":"http:\/\/eliteitsolution.com\/PSM\/?page_id=652"},"modified":"2014-03-10T12:31:34","modified_gmt":"2014-03-10T07:01:34","slug":"chemist-400","status":"publish","type":"page","link":"http:\/\/lpgsafety.com\/NLPG\/flue-gas-analysers\/chemist-400\/","title":{"rendered":"CHEMIST 400 &#8211; 4 Cells Combustion Analyser"},"content":{"rendered":"<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<div class=\"text1\" align=\"JUSTIFY\"><b>CHEMIST 401<\/b><br \/>\n2 sensors (O2, CO\/H2), not expandable, with built in impact printer, rechargeable Li-Ion batteries, with no dilution pump for CO.<b>CHEMIST 402<\/b><br \/>\n2 sensors (O2, CO\/H2), expandable up to 4 sensors, with built in impact printer, rechargeable Li-Ion batteries, with dilution pump for CO.<b>CHEMIST 403<\/b><br \/>\n3 sensors (O2, CO\/H2, NO), expandable up to 4 sensors, with built in mpact printer, rechargeable Li-Ion batteries, with dilution pump for<br \/>\nCO.<b>CHEMIST 404N<\/b><br \/>\n4 sensors (O2, CO\/H2, NO, NO2), with built in impact printer, rechargeable Li-Ion batteries, with dilution pump for CO.<\/p>\n<p><b>CHEMIST 404S<\/b><br \/>\n4 sensors (O2, CO\/H2, NO, SO2), with built in impact printer, rechargeable Li-Ion batteries, with dilution pump for CO.<\/p>\n<\/div>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"center\" valign=\"top\"><img loading=\"lazy\" decoding=\"async\" alt=\"single-gas-detector\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2013\/11\/CHEMIST-400.png\" width=\"487\" height=\"264\" \/><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"center\" valign=\"top\"><a href=\"?page_id=706\" target=\"_blank\"><br \/>\n<strong>Request a quote<\/strong><\/a><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"top\">\n<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><strong>All Kits include :<\/strong><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<ul>\n<li>hard ABS case,<\/li>\n<li>power supply with plug,<\/li>\n<li>300 mm flue gas sampling probe with 3 mts hose,<\/li>\n<li>water trap with dust filter,<\/li>\n<li>Pt100 outdoor air temperature sensor,<\/li>\n<li>differential pressure Kit,<\/li>\n<li>neoprene holster with magnets,<\/li>\n<li>printer paper roll,<\/li>\n<li>USB pendrive with software,<\/li>\n<li>USB PC connection cable,<\/li>\n<li>user manual<\/li>\n<li>calibration certificate<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><strong>Up to 4 measuring sensors for:<\/strong><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<ul>\n<li>02<\/li>\n<li>CO\/H2<\/li>\n<li>NO<\/li>\n<li>NO2<\/li>\n<li>SO2<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><strong>Other measurement:<\/strong><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<ul>\n<li>Flue Gas Temperature<\/li>\n<li>Outdoor Air Temperature<\/li>\n<li>Room Temperature<\/li>\n<li>Differential Temperature<\/li>\n<li>Draft and Differential pressure<\/li>\n<li>Ambient CO and NO<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><strong>Calculated Measurement :<\/strong><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<ul>\n<li>CO2<\/li>\n<li>NOX<\/li>\n<li>boiler efficiency, condensing included<\/li>\n<li>Stack loss<\/li>\n<li>Excess air<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><strong>Additional features:<\/strong><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<ul>\n<li>Gas piping tightness test<\/li>\n<li>High accuracy draft measurement<\/li>\n<li>Firmware updates available for free<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><strong>Main features:<\/strong><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<ul>\n<li>Compliant with EN 50379-1<\/li>\n<li>Up to 4 measurement cells: O2, CO\/H2, NO, NO2 and SO2<\/li>\n<li>CO measurement cell with 1 ppm resolution and built in NOX\/SOX filter<\/li>\n<li>Pre-calibrated gas sensors, field replaceable<\/li>\n<li>Flue gas and outdoor air temperature measurement<\/li>\n<li>Draft and differential pressure measurement<\/li>\n<li>Boiler efficiency calculation<\/li>\n<li>Automatic detection of condensing boiler with efficiency calculation<\/li>\n<li>CO2, heat stack loss, excess air calculation<\/li>\n<li>Ambient CO and NO measurement<\/li>\n<li>Gas pipe tightness test<\/li>\n<li>High accuracy (\u00b1 0.5 Pa) and resolution (0.1 Pa) draft measurement with external accessory<\/li>\n<li>3 consecutive analysis with average calculation and result printout<\/li>\n<li>Built in impact printer on plain paper (non thermal)<\/li>\n<li>Internal memory for 300 analysis<\/li>\n<li>Big blue (42 x 60 mm) graphic LCD backlit with zoom feature<\/li>\n<li>Rechargeable Lithium Ion batteries<\/li>\n<li>External Charger\/Power Supply with AC plug<\/li>\n<li>Recharging time: 2 hrs. up to 90%<\/li>\n<li>Up to 15 hrs. autonomy of continuous operation (no printouts)<\/li>\n<li>Up to 40 analysis autonomy (with printouts)<\/li>\n<li>Additional dilution pump for CO cell auto range, measurement up to 50,000 ppm<\/li>\n<li>Automatic Auto-zero with sampling probe in the stack<\/li>\n<li>PC software on USB pendrive and USB cable for unlimited data storage on PC<\/li>\n<li>Bluetooth communication<\/li>\n<li>Self diagnostic function with alarms on gas sensors end-of-life<\/li>\n<li>180, 300, 750 mm flue gas sensor probes<\/li>\n<li>220 mm flexible flue gas sensors sampling probe<\/li>\n<li>External condensation trap and dust filter<\/li>\n<li>Unbreakable stainless steel probe and hose connections<\/li>\n<li>10 preprogrammed fuels, including pellets and wood<\/li>\n<li>16 additional programmable fuels<\/li>\n<li>9 different languages preprogrammed<\/li>\n<li>Neoprene magnetic holster<\/li>\n<li>User manual and calibration certificate<\/li>\n<li>Dimensions 307x105x96 mm, weight 1,1 Kg.<\/li>\n<li>TUV Certified<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>CHEMIST 401 2 sensors (O2, CO\/H2), not expandable, with built in impact printer, rechargeable Li-Ion batteries, with no dilution pump for CO.CHEMIST 402 2 sensors (O2, CO\/H2), expandable up to 4 sensors, with built in impact printer, rechargeable Li-Ion batteries, with dilution pump for CO.CHEMIST 403 3 sensors (O2, CO\/H2, NO), expandable up to 4 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":409,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-652","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/comments?post=652"}],"version-history":[{"count":9,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/652\/revisions"}],"predecessor-version":[{"id":1674,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/652\/revisions\/1674"}],"up":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/409"}],"wp:attachment":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/media?parent=652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}