{"id":618,"date":"2013-11-23T10:25:20","date_gmt":"2013-11-23T10:25:20","guid":{"rendered":"http:\/\/eliteitsolution.com\/PSM\/?page_id=618"},"modified":"2014-03-09T22:44:39","modified_gmt":"2014-03-09T17:14:39","slug":"one-6-gas-detector","status":"publish","type":"page","link":"http:\/\/lpgsafety.com\/NLPG\/gas-leak-survey-detectors\/one-6-gas-detector\/","title":{"rendered":"One to 6 Gas Detector"},"content":{"rendered":"<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><strong>G 750<\/strong><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">The G750 is a versatile multi-gas monitor that offers up to 6 gas detection ranges.Available sensor combinations may include the detection of 0<sub>2<\/sub>,CO, H<sub>2<\/sub>S, SO<sub>2<\/sub>, NO<sub>2<\/sub>, CL<sub>2<\/sub>, HCN, NO, combustibles (% volume, % LEL) and CO<sub>2<\/sub>.<\/p>\n<p>The user can select diffusion or internal pump sampling, make this unit unequaled in the market.<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\" width=\"1%\"><\/td>\n<td align=\"left\" valign=\"top\">\n<ul>\n<li>Multi-gas monitor (1-to-6 detection ranges including<\/li>\n<li>Powerful datalogging<\/li>\n<li>Smart sensor technology<\/li>\n<li>Built-in pump allows user-selection of sample-draw or diffusion sampling<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\" valign=\"top\" width=\"1%\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"center\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"center\" valign=\"top\"><img loading=\"lazy\" decoding=\"async\" alt=\"single-gas-detector\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2013\/11\/One-6-Gas-Detector.png\" width=\"487\" height=\"269\" \/><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"center\" valign=\"top\"><a href=\"?page_id=706\" target=\"_blank\"><br \/>\n<strong>Request a quote<\/strong><\/a><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"center\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<div class=\"tb2-txt\" align=\"justify\"><b>Configured for your application<\/b><br \/>\nThe sensors in the G750 may be configured to best match your industry\u2019s needs.The S3 (smart sensor system) allows flexibility for the user to interchange sensors in the field.To alert the user to increasing hazards, the unit has up to three user adjustable alarm points..<\/p>\n<p><b>Powerful datalogging <\/b><br \/>\nThe G750 datalogging option provides storage capacity for more than 30 days of continuous operation.<\/p>\n<p>Downloading is easily done through the PC serial port that includes user name, location, and a detailed report of exposure levels and alarms.<\/p>\n<p>The user name and location can be edited with ease for your needs.<\/p>\n<p><b>Maintenance and security<\/b><br \/>\nMaintenance will never be missed with a user-determined inspection overdue alarm. Fresh air auto zeroing and AutoCal\u00ae calibration make routine maintenance effortless with no potentiometers to adjust.<\/p>\n<p>To prevent unauthorized changes to alarm values, a code must be used to enter advanced maintenance menus to make adjustments.<\/p>\n<\/div>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">\n<table width=\"100%\" border=\"1\" cellspacing=\"0\" cellpadding=\"1\" align=\"center\">\n<tbody>\n<tr>\n<td class=\"text1\" style=\"color: #fff;\" colspan=\"2\" align=\"CENTER\" bgcolor=\"#FF0000\"><b>Technical Data <\/b><\/td>\n<\/tr>\n<tr>\n<td class=\"text1\" colspan=\"2\" align=\"left\" valign=\"top\"><b>General<\/b><\/td>\n<\/tr>\n<tr>\n<td class=\"text1\" align=\"left\" valign=\"top\"><b>Gases<\/b><br \/>\nCarbon dioxide (IR) (CO<sub>2<\/sub>)<br \/>\nCarbon monoxide (CO)<br \/>\nChlorine (Cl<sub>2<\/sub>)<br \/>\nCombustible gases (CH<sub>4<\/sub>)<br \/>\nHydrogen cyanide (HCN)<br \/>\nHydrogen sulfide (H<sub>2<\/sub>S)<br \/>\nNitrogen dioxide (NO<sub>2<\/sub>)<br \/>\nNitrogen monoxide (NO)<br \/>\nOxygen (0<sub>2<\/sub>)<br \/>\nSulfur dioxide (SO<sub>2<\/sub>)s<\/td>\n<td class=\"text1\" align=\"left\" valign=\"top\"><b>Display<\/b><br \/>\nGraphic alpha-numeric display<b>Alarms <\/b><br \/>\nVisual &#8211; large red LED<br \/>\nAudible &#8211; buzzer, 80 dB<b>Operational time<\/b><br \/>\n7 to 14 hours (depending on sensors, alarms and sampling time<\/p>\n<p><b>Power source<\/b><br \/>\nRechargeable NiMH battery pack<\/td>\n<\/tr>\n<tr>\n<td class=\"text1\" align=\"left\" valign=\"top\"><b>Detection range <\/b><br \/>\nCH<sub>4<\/sub> 0-100% LEL or 0-100% volume<br \/>\nCl<sub>2<\/sub> 0-10 ppm<br \/>\nCO O-500 or 1,000 ppm<br \/>\nCO<sub>2 <\/sub>0-5%, 25%, 70% volume or 0-10,000 ppm<br \/>\nH<sub>2<\/sub>S 0-50 or 100 ppm<br \/>\nHCN 0-100 ppm<br \/>\nNO 0-100 ppm<br \/>\nNO<sub>2<\/sub> 0-50 ppm<br \/>\nO<sub>2<\/sub> 0-25% volume<br \/>\nSO<sub>2<\/sub> 0-20 ppm<\/td>\n<td class=\"text1\" align=\"left\" valign=\"top\"><b>Temperature range<\/b><br \/>\n+14 to +122\u00b0F \/ -10 to +50\u00b0C<b>Humidity range<\/b><br \/>\n0 (20) to 98% r.h. non-condensing<b>Pressure range <\/b><br \/>\n800 to 1,300 mbar<\/p>\n<p><b>Casing <\/b><br \/>\nCarbon fiber reinforced polyamide<\/p>\n<p><b>Weight<\/b><br \/>\n26 ounces (750 grams)<\/p>\n<p><b>Dimensions<\/b><br \/>\n8&#215;3.5&#215;2.5 inches (199x90x60 mm) (HxWxD)<\/td>\n<\/tr>\n<tr>\n<td class=\"text1\" align=\"left\" valign=\"top\"><b>Detection principles (sensors) <\/b><br \/>\nCH<sub>4<\/sub> \u00a0\u00a0\u00a0Catalytic combustion or thermal conductivity<br \/>\nO<sub>2<\/sub> and toxics \u00a0\u00a0\u00a0Electochemical<br \/>\nIR \u00a0\u00a0\u00a0Infra-red dual beam<\/td>\n<td class=\"text1\" align=\"left\" valign=\"top\"><b>Ratings and certifications<\/b> (intrinsic safety)<br \/>\nCENELEC EEX ibd IIC T5 UL Class I, Div. 1 A, B, C, D<\/td>\n<\/tr>\n<tr>\n<td class=\"text1\" align=\"left\" valign=\"top\"><b>Detection method<\/b><br \/>\nBuilt-in sampling pump and diffusion<b>Expected sensor life <\/b><br \/>\nCH<sub>4<\/sub> \u00a0\u00a0\u00a0Greater than 3 years<br \/>\nO<sub>2<\/sub> \u00a0\u00a0\u00a02 years<br \/>\nIR, toxics \u00a0\u00a0\u00a0Greater than 3 years<\/td>\n<td class=\"text1\" align=\"left\" valign=\"top\"><b>Options<\/b><br \/>\nDatalogging kit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>G 750 The G750 is a versatile multi-gas monitor that offers up to 6 gas detection ranges.Available sensor combinations may include the detection of 02,CO, H2S, SO2, NO2, CL2, HCN, NO, combustibles (% volume, % LEL) and CO2. The user can select diffusion or internal pump sampling, make this unit unequaled in the market. Multi-gas [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":401,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-618","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/comments?post=618"}],"version-history":[{"count":8,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/618\/revisions"}],"predecessor-version":[{"id":1556,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/618\/revisions\/1556"}],"up":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/401"}],"wp:attachment":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/media?parent=618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}