{"id":1540,"date":"2014-03-05T14:23:46","date_gmt":"2014-03-05T08:53:46","guid":{"rendered":"http:\/\/lpgsafety.com\/NLPG\/?page_id=1540"},"modified":"2014-03-10T12:32:46","modified_gmt":"2014-03-10T07:02:46","slug":"lel-transmitter-cgt-2000","status":"publish","type":"page","link":"http:\/\/lpgsafety.com\/NLPG\/gas-transmitters-combustibles-hazardous-area-4-20-ma\/lel-transmitter-cgt-2000\/","title":{"rendered":"Diffusion Sensor\/Transmitter  for  Combustible Gases &#8211; S2000 Series"},"content":{"rendered":"<p>S2000 Series combustible gas sensor \/transmitters are highly reliable and very cost effective for detection of all combustible gases. \u00a0These\u00a0sensors have been used under diverse ambient conditions including Off-shore. The sensor works on the catalytic oxidation principal and generates an electrical signal depending upon gas concentration in air.\u00a0 These sensors are used over 0-100% LEL (Lower Explosive Limit) of gas concentration in standard air. These sensors respond to all combustible gases. Sensors can be calibrated to respond to a specific gas. These sensors are rugged in design and do not generate false response like Semiconductor sensors.<\/p>\n<p>This model is available with following variations:<\/p>\n<p>1. Sensor &#8211; Catalytic Combustion OR Dual Beam Infra-red.<\/p>\n<p>2. Operating Voltage &#8211; 9-24 V DC OR 15-37 V DC<\/p>\n<p>3. Enclosure &#8211; Flameproof Weatherproof IP55 as per IEC 60079 &amp; PESO approved OR\u00a0Flameproof Weatherproof IP65 compaliant with IEC 60079<\/p>\n<p>The transmitter contains all the circuits to provide regulated Sensor drive, pre-amplifiers for both reference and detection channels, circuits for all processing operations and calibration controls etc.<\/p>\n<p>Each transmitter is factory calibrated for one or two gases (Dual Gas version) Methane and Iso-butane). Alternately it can be given for any two gases as desired. User can select any of these two gases on site without necessity of re-calibration.<\/p>\n<p>It generates industry standard 4-20mA output for three-wire, remote monitoring host systems like Control Panels, DCS, PLC, or any 4-20mA receiver or Prism \u00a0family of Monitors \u00a0or SCADA systems.<\/p>\n<p>&nbsp;<\/p>\n<table width=\"100%\" border=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<h3><strong>Features<\/strong><\/h3>\n<ul>\n<li>Dual Matched Pellistor<\/li>\n<li>Automatic ambient temperature compensation<\/li>\n<li>Weather-proof Enclosure IP55<\/li>\n<li>Operating over wide voltage 9-24 V dc<\/li>\n<li>Sensor c\/w configured and pre-calibrated Transmitter<\/li>\n<li>Resistant to catalytic poisons<\/li>\n<li>Excellent long term Zero and Sensitivity stability<\/li>\n<li>No False Alarms<\/li>\n<li>Linear 4-20mA current source output<\/li>\n<li>Reverse polarity protection &#8211; Both Signal and Output<\/li>\n<li>Continuous fault monitoring<\/li>\n<li>Very low power efficiency using DC-DC converter<\/li>\n<li>Local Zero and Span calibration controls<\/li>\n<li>One man calibration w\/o breaking current loop<\/li>\n<li>On board LED for operation status<\/li>\n<\/ul>\n<h3><b>\u00a0<\/b><strong><br \/>\n<\/strong><\/h3>\n<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" alt=\"\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2014\/02\/DU2200.jpg\" width=\"109\" height=\"102\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b style=\"line-height: 1.5em;\"><i>Technical specifications<\/i><\/b><b style=\"line-height: 1.5em;\">\u00a0<i>:<\/i><\/b><\/p>\n<p>&nbsp;<\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"223\">Sensor<\/td>\n<td valign=\"top\" width=\"353\">Catalytic Comb., Infra-red<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Type<\/td>\n<td valign=\"top\" width=\"353\">Diffusion<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Signal output<\/td>\n<td valign=\"top\" width=\"353\">4-20 mA proportional output<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Visual Indication<\/td>\n<td valign=\"top\" width=\"353\">Pilot LED<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Power supply<\/td>\n<td valign=\"top\" width=\"353\">9-24 VDC normal or 15-70 V DC extended<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Signal Outputs<\/td>\n<td valign=\"top\" width=\"353\">3 wire 4-20 mA<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\"><\/td>\n<td valign=\"top\" width=\"353\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Current consumption<\/td>\n<td valign=\"top\" width=\"353\">&lt;100 mA @ 12 V DC&lt;70 mA @ 24V DC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\"><\/td>\n<td valign=\"top\" width=\"353\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Warm-Up time<\/td>\n<td valign=\"top\" width=\"353\">Max. 5 minutes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\"><\/td>\n<td valign=\"top\" width=\"353\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Operating Temperature<\/td>\n<td valign=\"top\" width=\"353\">-10 \u00baC to +50 \u00baC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\"><\/td>\n<td valign=\"top\" width=\"353\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Relative Humidity<\/td>\n<td valign=\"top\" width=\"353\">20-90 % RH, Non condensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Pressure<\/td>\n<td valign=\"top\" width=\"353\">90-110 KPa<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Air Velocity<\/td>\n<td valign=\"top\" width=\"353\">&lt; 0.1- 0.5 m\/s<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Calibration<\/td>\n<td valign=\"top\" width=\"353\">Thru on-board Zero and Span screw drive controls<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Dimensions (H x L x D)mm<\/td>\n<td valign=\"top\" width=\"353\">[158 x 82(+28mm with brackets) \u00a0x 85]mm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Weight<\/td>\n<td valign=\"top\" width=\"353\">Less than 350 gms<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Mounting<\/td>\n<td valign=\"top\" width=\"353\">Wall\/Floor \u00a0with Brackets\/Stand<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Enclosure<\/td>\n<td valign=\"top\" width=\"353\">Weatherproof IP65<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Enclosure Material<\/td>\n<td valign=\"top\" width=\"353\">ABS or Cast Al alloy LM6<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Sensor Housing<\/td>\n<td valign=\"top\" width=\"353\">SS 304\/316<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Connections<\/td>\n<td valign=\"top\" width=\"353\">3 Screw terminal (Wire dia 0.2-2.5 mmsq)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>Gases ( 0-100% LEL or 0-50%LEL)<\/b><\/p>\n<p><b>LPG, Methane, Gasoline, Propane, Hexane, Pentane, Toluene, ABS \u00a0.. all combustible vapors<\/b><\/p>\n<p><span style=\"line-height: 1.5em;\">\u00a0<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>S2000 Series combustible gas sensor \/transmitters are highly reliable and very cost effective for detection of all combustible gases. \u00a0These\u00a0sensors have been used under diverse ambient conditions including Off-shore. The sensor works on the catalytic oxidation principal and generates an electrical signal depending upon gas concentration in air.\u00a0 These sensors are used over 0-100% LEL [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1405,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-1540","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/comments?post=1540"}],"version-history":[{"count":5,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1540\/revisions"}],"predecessor-version":[{"id":1545,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1540\/revisions\/1545"}],"up":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1405"}],"wp:attachment":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/media?parent=1540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}