{"id":1394,"date":"2014-02-21T13:40:36","date_gmt":"2014-02-21T08:10:36","guid":{"rendered":"http:\/\/lpgsafety.com\/NLPG\/?page_id=1394"},"modified":"2014-03-11T13:19:34","modified_gmt":"2014-03-11T07:49:34","slug":"gas-transmitters-toxic-combustibles-pid-oxygen","status":"publish","type":"page","link":"http:\/\/lpgsafety.com\/NLPG\/gas-transmitters-toxic-combustibles-pid-oxygen\/","title":{"rendered":"Toxic Gases &#8211; non Hazardous Area &#8211; Analog, Digital"},"content":{"rendered":"<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\">Prism has a variety of transmitters for very large range of toxic gases for diverse applications.<\/p>\n<p>All transmitters are housed in weather proof enclosures and use different sensing technologies \u00a0&#8211; Electro-chemical, PID, Zirconia, Chemosorption etc. The Units are provided with suitable mounting brackets for wall or pipe mounting and the sensor always faces downwards. All these measure the gas concentration in the sensor surroundings and convert measured gas into 4-20mA electrical signal. The sensors are designed to respond selectively to the target gas but can respond to other interfering gases. Understanding of the composition of environment is essential to select sensor or to interpret results properly.<\/p>\n<p>Available variants are &#8211;<\/p>\n<ol>\n<li>2 wire\/3 wire<\/li>\n<li>Blind\/Indicating ( with LED digital display)\/Indicating ( with LCD digital display)<\/li>\n<li>With settable alarms and relay outputs for local control<\/li>\n<li>Digital models with RS485 HART\/ Serial Modbus output<\/li>\n<\/ol>\n<p>These can be used with any of PRISM Monitors and\/or third party Receivers, PLC, DCS etc.<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\"><strong>TGT 1000 &#8211; Toxic Gas Transmitter 2 wire<\/strong><\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"top\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2013\/11\/tgt-1000.jpg\" width=\"150\" height=\"148\" \/><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">TGT 1000 is a series of direct use Sensor + Transmitter combination units housed in weather-proof (IP65) ABS enclosures.<\/p>\n<p>Available for large number of gases &#8211; CO, H2S, SO2, NO2, NO, Cl2, HCN, HCL, O2, PH3, ETO, NH3.<\/p>\n<p>Available with HART output, digital display, two alarms &amp; relay output variations. \u00a0<strong><a title=\"TGT-1000D\" href=\"http:\/\/lpgsafety.com\/NLPG\/?page_id=1332\">More\u2026\u2026<\/a><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\"><strong>TGT 1550 &#8211; Toxic Gas Transmitter 3 wire<\/strong><\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"top\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2014\/02\/DU1550.png\" width=\"100\" height=\"190\" \/><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">TGT 1550 \u00a0is a series of direct use Sensor + Transmitter combination units housed in weather-proof (IP65) ABS enclosures. In addition to 4-20 mA output these transmitters provide special features like Serial Communication port, storage of Sr. No \/Lot No., date of calibration, Digital filtering algorithm to remove noise.<\/p>\n<p>Available for large number of gases &#8211; CO, H2S, NO2, O2, NH3.<\/p>\n<p>Available with RS485 Modbus output, digital display, three alarms &amp; relay output variations.\u00a0<span style=\"font-size: 11px; line-height: 1.5em;\">\u00a0\u00a0<\/span><strong style=\"font-size: 11px; line-height: 1.5em;\"><a title=\"Toxic Gas Transmitter TGT 1550 3 Wire\" href=\"http:\/\/lpgsafety.com\/NLPG\/toxic-gas-transmitter-tgt-1550-3-wire\/\">More\u2026\u2026<\/a><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\"><strong>ZD 21 &#8211; Oxygen Gas Transmitter 3 wire<\/strong><\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"top\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2014\/02\/zd21.jpg\" width=\"100\" height=\"90\" \/><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">ZD 21 \u00a0is a Zirconia Sensor based transmitter. Extremely stable sensor, long life &#8211; 5 years, fast response &#8211; \u00a0 &lt; 2secs. is a direct use Sensor + Transmitter combination unit housed in weather-proof (IP65) rugged aluminium enclosure. It outputs 4-20 mA analog signal and operates over -25 to 50 degC. The external circuit of \u00a0Receiver is connected to the transmitter via a screw terminal Connector.. \u00a0<strong><a title=\"Web-page Under Development.\" href=\"http:\/\/lpgsafety.com\/NLPG\/web-page-development\/\">More\u2026\u2026<\/a><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\"><strong>\u00a0CS 21 &#8211; Ammonia Gas Transmitter for\u00a0Refrigeration\u00a0Plants &#8211; 3 wire<\/strong><\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"top\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2014\/02\/cs21.jpg\" width=\"100\" height=\"90\" \/><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">CS 21 \u00a0uses Chemosorpton based sensor. Long life \u00a0of over 5 years, fast response &#8211; \u00a0 &lt; 8 secs. is a direct use Sensor + Transmitter combination unit housed in weather-proof (IP54) rugged aluminium enclosure. It outputs 4-20 mA analog signal and operates over -30 to 55 degC. The external circuit of \u00a0Receiver is connected to the transmitter via a screw terminal Connector.. \u00a0<strong><a title=\"Web-page Under Development.\" href=\"http:\/\/lpgsafety.com\/NLPG\/web-page-development\/\">More\u2026\u2026<\/a><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Prism has a variety of transmitters for very large range of toxic gases for diverse applications. All transmitters are housed in weather proof enclosures and use different sensing technologies \u00a0&#8211; Electro-chemical, PID, Zirconia, Chemosorption etc. The Units are provided with suitable mounting brackets for wall or pipe mounting and the sensor always faces downwards. All [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-1394","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1394","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/comments?post=1394"}],"version-history":[{"count":15,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1394\/revisions"}],"predecessor-version":[{"id":1535,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1394\/revisions\/1535"}],"wp:attachment":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/media?parent=1394"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}