{"id":1332,"date":"2014-02-16T22:36:48","date_gmt":"2014-02-16T17:06:48","guid":{"rendered":"http:\/\/lpgsafety.com\/NLPG\/?page_id=1332"},"modified":"2014-03-19T15:46:58","modified_gmt":"2014-03-19T10:16:58","slug":"tgt-1000d","status":"publish","type":"page","link":"http:\/\/lpgsafety.com\/NLPG\/gas-transmitters-toxic-combustibles-pid-oxygen\/tgt-1000d\/","title":{"rendered":"TGT-1000"},"content":{"rendered":"<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\">\n<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\" width=\"85%\"><strong>Toxic Gas Transmitter TGT 1000<\/strong><\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"top\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2013\/11\/tgt-1000.jpg\" width=\"150\" height=\"148\" \/><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">TGT 1000 is a series of direct use Sensor + Transmitter combination units housed in weather-proof (IP65) enclosures. \u00a0Transmitters are designed for standard two-wire operation where the output is supplied via the same wire pair as the power supply. The external circuit loop is connected to the transmitter via a screw terminal Connector.The \u00a0Units \u00a0are \u00a0supplied \u00a0pre-calibrated\u00a0 for \u00a0the \u00a0specified range, and the sensitivity of the device should not drift by more than 2% of full signal per month. Some sensors have cross interference effect of \u00a0other gases. It is important to specify air composition to help choose appropriate sensor.Except\u00a0 requiring \u00a0periodic\u00a0 re-calibration,\u00a0 transmitters \u00a0are maintenance-free,\u00a0\u00a0 \u00a0and\u00a0\u00a0 \u00a0should \u00a0 give faultless service throughout the working life of the sensor.TGT is available with \u00a0many \u00a0 \u00a0optional enhancements like 4 digit \u00a0LED \u00a0display, \u00a0multi-parameter back \u00a0lit LCD \u00a0display. HART \u00a0protocol \u00a0output. \u00a0Modbus \u00a0protocol, \u00a0PC \u00a0calibration and programming facility etc.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"center\" valign=\"top\"><strong>Request a quote<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">\u00a0<strong>Features:<\/strong><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">\n<ul>\n<li>Very Low Maintenance<\/li>\n<li>High Sensitivity Sensor<\/li>\n<li>4 digit LED display<\/li>\n<li>Microcontroller SMD Components<\/li>\n<li>Weather proof ABS Dust Tight IP 65 enclosure<\/li>\n<li>Aeasthetical Looks<\/li>\n<li>2 Wire 4-20 mA output<\/li>\n<li>Loop Powered<\/li>\n<li>Wide optg Voltage. 10-27VDC<\/li>\n<li>Compatible \u2013 DCS, PLC, PRISM Monitors<\/li>\n<\/ul>\n<\/td>\n<td align=\"left\" valign=\"top\"><span style=\"font-family: sans-serif; font-size: medium;\">\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr><!-- Row 1 --><\/p>\n<td style=\"text-align: center;\" valign=\"top\" width=\"223\"><strong>Gas<\/strong><\/td>\n<p><!-- Col 1 --><\/p>\n<td style=\"text-align: center;\" valign=\"top\" width=\"353\"><strong>Ranges Available<\/strong><\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 2 --><\/p>\n<td>Carbon Monoxide CO<\/td>\n<p><!-- Col 1 --><\/p>\n<td>2000, 5000, 10,000 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 3 --><\/p>\n<td>Hydrogen Sulphide H<sub>2<\/sub>S<\/td>\n<p><!-- Col 1 --><\/p>\n<td>50, 200, 1000, 2000 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 4 --><\/p>\n<td>Sulphur Dioxide SO<sub>2<\/sub><\/td>\n<p><!-- Col 1 --><\/p>\n<td>20, 100, 2000 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 5 --><\/p>\n<td>Nitorogen Dioxide NO<sub>2<\/sub><\/td>\n<p><!-- Col 1 --><\/p>\n<td>20 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 6 --><\/p>\n<td>Chlorine Cl<sub>2<\/sub><\/td>\n<p><!-- Col 1 --><\/p>\n<td>10, 20 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 7 --><\/p>\n<td>Nitric Oxide NO<\/td>\n<p><!-- Col 1 --><\/p>\n<td>250, 5000 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 8 --><\/p>\n<td>Phosphene PH<sub>3<\/sub><\/td>\n<p><!-- Col 1 --><\/p>\n<td>10 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 9 --><\/p>\n<td>Ethylene Oxide E<sub>2<\/sub>O<\/td>\n<p><!-- Col 1 --><\/p>\n<td>100 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 10 --><\/p>\n<td>Hydrogen Cyanide HCN<\/td>\n<p><!-- Col 1 --><\/p>\n<td>100 ppm<\/td>\n<p><!-- Col 2 --><\/tr>\n<tr><!-- Row 11 --><\/p>\n<td>Oxygen O<sub>2<\/sub><\/td>\n<p><!-- Col 1 --><\/p>\n<td>25% Vol<\/td>\n<p><!-- Col 2 --><\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><b><i><span style=\"text-decoration: underline;\">Technical specifications<\/span><\/i><\/b><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"223\">Sensor<\/td>\n<td valign=\"top\" width=\"353\">Electrochemical, Galvanic<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Type<\/td>\n<td valign=\"top\" width=\"353\">Diffusion, Suction ( optional)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Signal output<\/td>\n<td valign=\"top\" width=\"353\">4-20 mA proportional output<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Sensor out of range<\/td>\n<td valign=\"top\" width=\"353\">&gt; 21.5 mA<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Power supply<\/td>\n<td valign=\"top\" width=\"353\">\u00a010 -30 V DC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Digital Output<\/td>\n<td valign=\"top\" width=\"353\">HART \u00a0RS485 Modbus<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Protection<\/td>\n<td valign=\"top\" width=\"353\">Reverse Connection<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\"><\/td>\n<td valign=\"top\" width=\"353\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Warm-Up time<\/td>\n<td valign=\"top\" width=\"353\">Max. 2 minutes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Stabilization time<\/td>\n<td valign=\"top\" width=\"353\">Less than 2 minutes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Operating Temperature<\/td>\n<td valign=\"top\" width=\"353\">-20 \u00baC to +50 \u00baC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\"><\/td>\n<td valign=\"top\" width=\"353\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Relative Humidity<\/td>\n<td valign=\"top\" width=\"353\">0-95 % RH, Non condensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Pressure<\/td>\n<td valign=\"top\" width=\"353\">90-110 KPa<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\"><\/td>\n<td valign=\"top\" width=\"353\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Calibration<\/td>\n<td valign=\"top\" width=\"353\">Either Digitally, Via HART RS485 Interface or with Zero\/SPAN controls<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Max Loop Res.<\/td>\n<td valign=\"top\" width=\"353\">700 R at 24V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Weight<\/td>\n<td valign=\"top\" width=\"353\">Less than 250 gms<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Mounting<\/td>\n<td valign=\"top\" width=\"353\">Wall\/Floor \u00a0with Brackets\/Stand<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Enclosure<\/td>\n<td valign=\"top\" width=\"353\">Weatherproof IP65<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Enclosure Material<\/td>\n<td valign=\"top\" width=\"353\">ABS<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Sensor Housing<\/td>\n<td valign=\"top\" width=\"353\">PVC,SS (Optional)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"223\">Connections<\/td>\n<td valign=\"top\" width=\"353\">2 Screw terminal (Wire dia 0.2-2.5 mmsq)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Toxic Gas Transmitter TGT 1000 TGT 1000 is a series of direct use Sensor + Transmitter combination units housed in weather-proof (IP65) enclosures. \u00a0Transmitters are designed for standard two-wire operation where the output is supplied via the same wire pair as the power supply. The external circuit loop is connected to the transmitter via a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1394,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-1332","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/comments?post=1332"}],"version-history":[{"count":11,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1332\/revisions"}],"predecessor-version":[{"id":1645,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1332\/revisions\/1645"}],"up":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1394"}],"wp:attachment":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/media?parent=1332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}