{"id":1155,"date":"2014-03-10T16:21:47","date_gmt":"2014-03-10T10:51:47","guid":{"rendered":"http:\/\/lpgsafety.com\/NLPG\/?page_id=1155"},"modified":"2014-03-10T16:47:23","modified_gmt":"2014-03-10T11:17:23","slug":"duomon","status":"publish","type":"page","link":"http:\/\/lpgsafety.com\/NLPG\/pre-configured-compact-multi-channel-monitors\/supermons\/duomon\/","title":{"rendered":"DuoMon"},"content":{"rendered":"<h3><strong>Compact Area Monitors<\/strong><\/h3>\n<p>DuoMon is a \u00a0compact Gas \u00a0Monitor that accurately measures combustible gases, toxic gases and oxygen levels. Many of these can be connected in multi drop RS485 loop form for centralized monitoring. Alternately these can be put on plant LAN for centralized monitoring. Three Alarms, in-built hysteresis, universal power input, variety of Audio-visual alarm devices, 3 digit LED display,\u00a0 variable ranges \u2013 LEL, Vol., ppm \u2013 all these make this Monitor a power house of gas monitoring systems.<\/p>\n<p><b>Simple and effective<\/b><\/p>\n<p>The unit accurately displays measured gas concentration on a large 3 digit LED display. The display also shows text messages related to channel status and system status. Compact and simple design facilitates easy do-it-yourself type installation. Pre-calibrated Sensors allow direct commissioning without need of skilled manpower. Monitor is equipped with onboard relays for three alarm points and fault. These relays can be used to drive external devices like strobes, fans, voice alarms, auto-dialers, etc.<\/p>\n<p><a href=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2013\/11\/duomon.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-513\" alt=\"duomon\" src=\"http:\/\/lpgsafety.com\/NLPG\/wp-content\/uploads\/2013\/11\/duomon.jpg\" width=\"150\" height=\"148\" \/><\/a>\u00a0 \u00a0 \u00a0<a href=\"http:\/\/lpgsafety.com\/NLPG\/?page_id=706\" target=\"_blank\"><strong>Request a quote<\/strong><\/a><\/p>\n<ul>\n<li>\u00a0 \u00a0 \u00a0 \u00a0 Microcontroller, SMD components<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Addressable RS485 multi drop<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Three user Settable Alarms AL1, AL2, AL3 for each channel<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 4 LED Indications viz :\u00a0 AL1, AL2, AL3, Fault for each channel<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 3 Digit( 7-seg) \u00a0LED Display for each \u2013 Gas Conc. &amp; Messages<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 4 relay O\/Ps : AL1, AL2, AL3, Fault<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Built in Multi-function Audio Buzzer<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 3 Programme &amp; \u00a0Operation Non-intrusive Switch controls<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Compact IP65 Weatherproof Enclosure<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Universal Input Supply : 100-260VAC, 50-60Hz<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Independent range &amp; scale for each channel \u2013 ppm, %Vol., % LEL<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 In-built hysteresis \u2013 no false alarms or jittering<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 User Programmable functions.- Alarm Thresholds, Ch. Inhibit, Ch. Skip,<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Factory settable functions \u2013 Scale, Range, Alarms Latching\/non-latching,\u00a0 Alarm Increasing\/decreasing, Hysteresis<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Programming Port \u2013 RS232\/Blue Tooth\/Ethernet<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 All cables thru IP65 glands and Plug-Socket screw connectors<\/li>\n<li>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Display\u00a0 msgs \u2013 nor, inh, sp, ok,al1,al2,al3,run, prog, quad 4 ch,<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Compact Area Monitors DuoMon is a \u00a0compact Gas \u00a0Monitor that accurately measures combustible gases, toxic gases and oxygen levels. Many of these can be connected in multi drop RS485 loop form for centralized monitoring. Alternately these can be put on plant LAN for centralized monitoring. Three Alarms, in-built hysteresis, universal power input, variety of Audio-visual [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1242,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-1155","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/comments?post=1155"}],"version-history":[{"count":10,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1155\/revisions"}],"predecessor-version":[{"id":1563,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1155\/revisions\/1563"}],"up":[{"embeddable":true,"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/pages\/1242"}],"wp:attachment":[{"href":"http:\/\/lpgsafety.com\/NLPG\/wp-json\/wp\/v2\/media?parent=1155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}